Sign In | Join Free | My tjskl.org.cn
China Biovantion Inc. logo
Biovantion Inc.
Concentrate on IVD reagents
Verified Supplier

4 Years

Home > Elisa Test Kit >

11-dehydro-Thromboxane B2 11dhTxB₂ ELISA Test Kit IVD High Accuracy And Simple Operation

Biovantion Inc.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

11-dehydro-Thromboxane B2 11dhTxB₂ ELISA Test Kit IVD High Accuracy And Simple Operation

  • 1
  • 2
  • 3

Brand Name : BIOVANTION

Model Number : TY0031

Certification : ISO 13485

Place of Origin : CHINA

MOQ : 1000 Box

Price : discussible

Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram

Supply Ability : 100000 Box/carton

Delivery Time : 2-7 days

Packaging Details : carton/box

Delivery : Within 48 hours

Packaging Specifications : 8 x 12 strips, 96 wells

Country Of Origin : China,BeiJing

Detection Limit : 18 months

Storage : 2-8℃

Specimen : Whole blood

Assification : class1

Product Type : Elisa Test Kit

Contact Now

11dhTxB₂ ELISA Test Kit

INTENDED USE

Complete ELISA kit-ready-to-use reagents

96-well microplate format

Single wash step

Assay time-2.5 hours

BACKGROUND

1.Aspirin,the foundation of antiplatelet therapy in cardiovascular medicine,is widely prescribed by physicians to prevent heart attack and stroke.It is estimated that more than 150,000 heart attacks each year could be prevented by the appropriate use of aspirin therapy.

2.Recently,physicians discovered that a significant number of individuals taking dosages of aspirin

considered therapeutic were experiencing vascular thrombotic events including acute coronary

syndromes,transient ischemic attacks,strokes and peripheral vascular events.In addition,clinical researchers,utilizing a variety of laboratory tests, discovered that some patients have a reduced or minimal response to aspirin administration.

3.Test Kit is a quantitative enzyme-linked immunoassay (ELISA)to determine levels of 11-dehydro thromboxane B2 (11dhTxB2) in human urine,which aids in the determination of platelet response to aspirin ingestion.

Product list

Product details Description
Delivery Within 48 hours
Packaging Specifications 5*8 x 12 strips, 480 wells
Country Of Origin China
Manufacturer 18 months
Preservation method 2℃-8℃
Specimen Urine
Assification class1
Type Elisa Test Kit

11-dehydro-Thromboxane B2 11dhTxB₂ ELISA Test Kit IVD High Accuracy And Simple Operation

11-dehydro-Thromboxane B2 11dhTxB₂ ELISA Test Kit IVD High Accuracy And Simple Operation11-dehydro-Thromboxane B2 11dhTxB₂ ELISA Test Kit IVD High Accuracy And Simple Operation11-dehydro-Thromboxane B2 11dhTxB₂ ELISA Test Kit IVD High Accuracy And Simple Operation11-dehydro-Thromboxane B2 11dhTxB₂ ELISA Test Kit IVD High Accuracy And Simple Operation

PRINCIPLE AND PROCEDURE

Test Kit measures urinary 11-dehydrothromboxane B2(11dhTxB2)and is performed as acompetitive ELISA.Diluted samples,purified 11dhTxB2 conjugated to alkaline phosphatase(AP),purified mouse monoclonal antibody directed to 11dhTxB2 are combined and incubated in microwells coated with a polyclonal anti-mouse antibody. Incubation allows the endogenous 11dhTxB2 present in the samples to compete with the purified AP-conjugated 11dhTxB2 for binding to the mouse monoclonal anti-11dhTxB2 antibody.The monoclonal antibody then binds to the polyclonal anti-mouse antibody coated on the microtiter plate.The complex formed on the plate is composed of monoclonal antibody and endogenous or AP-conjugated 11dhTxB2.After the removal of unbound complexes by washing,the bound AP-11dhTxB2 conjugate is assayed by the addition of paranitrophenylphosphate (pNPP)chromogenic substrate.Color develops in the wells at an intensity inversely proportional to the sample urine concentration of 11dhTxB2,and is read on a spectrophotometer at 405nm.Results (pg/mL)are calculated against a reference curve prepared from the Reference Solution provided in the kit.Final results are reported as pg 11dhTxB2 per mg creatinine to normalize results for urine concentration.

CLINICAL PERFORMANCE

Results are presented as positive or negative,based on a cutoff of 1500 pg 11-dehydro thromboxane B2 per mg urinary creatinine.The detection range for 11-dehydro thromboxane B2 in the test is 300-4000 pg/mL urine.For greatest accuracy,samples that generate values greater than 4000 pg/mL should be retested at an appropriate dilution.The analyte concentration reported should be normalized by dividing the measured 11 dhTxB2 by the concentration of urine creatinine as measured by a separate assay.The test kit was evaluated for intra-assay(72 replicates per sample within 1 kit lot)and inter- assay(216 replicates per sample over 3 kit lots) precision using the kit urine controls.Results are summarized in the following table:

Control

Overall Mean 11-dehydro thromboxane B2Concentration Intra-assay mean CV% Inter-assay mean CV%
1 548 pg/mL 10% 13%
2 915 pg/mL 5% 8%
3 1765 pg/mL 4% 5%

FEATURE

· Random Urine Sample

· Results reported as:

≤1500 pg 11dhTxB₂/mg of creatinine=ASPIRIN RESPONDER

>1500 pg 11dhTxB₂/mg of creatinine=ASPIRIN NON-RESPONDER

· Urinary 11-dehydro Thromboxane B₂ measurement

· Quantitative measurement of 11-dehydro Thromboxane B₂in human urine which aids in the qualitative detection of acetylsalicylic acid (ASA)effect

· NEW CAP(College of American Pathologists) proficiency sample available beginning 2012. Three (3)samples twice per year-listed under CAP:COAGULATION Code TBX

· Assay formats available for both manual and select automated platforms

PREPARATIONS

1. Allow all specimens and reagents to reach room temperature (~25°C) and mix thoroughly by gentle inversion before use.

2.Prepare Wash Buffer by diluting Wash Concentrate 20-fold with deionized water. The diluted wash solution is stable in room temperature for at least one week.

  • 11-dehydro-Thromboxane B2 11dhTxB₂ ELISA Test Kit IVD High Accuracy And Simple Operation

PRECAUTION FOR USERS

1. Handling should preclude any pipetting by mouth. Use only pipettes with disposable tips for each specimen.

2.Do not mix materials from different master lots. Do not use kit components beyond the expiration date.

3.All materials should be brought to room temperature before use.

11-dehydro-Thromboxane B2 11dhTxB₂ ELISA Test Kit IVD High Accuracy And Simple Operation11-dehydro-Thromboxane B2 11dhTxB₂ ELISA Test Kit IVD High Accuracy And Simple Operation11-dehydro-Thromboxane B2 11dhTxB₂ ELISA Test Kit IVD High Accuracy And Simple Operation


Product Tags:

High accuracy ELISA Test Kit

      

simple operation ELISA Test Kit

      
Quality 11-dehydro-Thromboxane B2 11dhTxB₂ ELISA Test Kit IVD High Accuracy And Simple Operation for sale

11-dehydro-Thromboxane B2 11dhTxB₂ ELISA Test Kit IVD High Accuracy And Simple Operation Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Biovantion Inc.
*Subject:
*Message:
Characters Remaining: (0/3000)